© 2003, Adaptec, Inc.
155
178
Name
MLXEV_SYSDEV_BG_INIT_PAUSED
Description Logical drive background initialization paused.
Cause
Background initialization paused due to a higher priority operation.
Action
None
Address
ctl: 0 logdrv: 15
Severity
4 (Information)
Source
ExPro
179
Name
MLXEV_SYSDEV_BG_INIT_RESTARTED
Description Logical drive background initialization restarted.
Cause
Background initialization started after being paused.
Action
None
Address
ctl: 0 logdrv: 15
Severity
4 (Information)
Source
ExPro
180
Name
MLXEV_SYSDEV_BG_INIT_FAILED
Description Logical drive background initialization failed.
Cause
Background initialization failed.
Action
None
Address
ctl: 0 logdrv: 15
Severity
2 (Error)
Source
ExPro
181
Name
MLXEV_SYSDEV_BG_INIT_COMPLETED
Description Logical drive background initialization completed.
Cause
Background initialization completed successfully.
Action
None
Address
ctl: 0 logdrv: 15
Severity
4 (Information)
Source
ExPro
182
Name
MLXEV_SYSDEV_DATA_LOSS_LOW_BBU_CHARGE
Description Low battery charge level. Logical drive may have lost data.
Cause
Controller was powered off for duration longer than battery capacity.
User connected a new controller.
User connected a new BBU battery.
Action
Run consistency check to verify logical drive consistency.
If needed, restore data from backup.
Address
ctl: 0 logdrv: 15
Severity
2 (Error)
Source
InPro
256
Name
MLXEV_FMTFAN_FAILED
Description Fan failure.
Cause
Cable connection broken.
Fan failure.
Action
Replace fan.
Address
ctl: 0 enclosure: 13 unit: 14
Severity
1 (Serious)
Source
ExP_old InP_old
257
Name
MLXEV_FMTFAN_OK
Description Fan has been restored.
Cause
Cable is connected properly.
Faulty fan has been replaced.
Action
None
Address
ctl: 0 enclosure: 13 unit: 14
Severity
4 (Information)
Source
ExP_old InP_old
Table 2
RAID Controller Event Codes
Содержание MAN-00005-UG
Страница 11: ...12 Spheras Storage Director Installation and User Guide ...
Страница 28: ... 2003 Adaptec Inc 29 Figure 12 Installation Welcome ...
Страница 34: ... 2003 Adaptec Inc 35 Figure 19 Client installation complete ...
Страница 53: ...54 Spheras Storage Director Installation and User Guide ...
Страница 65: ...66 Spheras Storage Director Installation and User Guide ...
Страница 117: ...118 Spheras Storage Director Installation and User Guide Figure 87 Displaying Physical Drive Information text view ...
Страница 192: ... 2003 Adaptec Inc 193 Figure 105 Open Image File Dialog Box ...
Страница 199: ...200 Spheras Storage Director Installation and User Guide ...