Technical Data
97/ 122
Powerlift prefabricated pumping station
6.2.3 SAT-V 75/2/50/D and SAT-V 150/2/50/D
Characteristic data and use limits
Key data
SAT-V
75/2/50/D
150/2/50/D
Type of cable for connection cable:
4G1
4G1
Pump motor operating voltage [V]:
400
400
Frequency [Hz]:
50
50
Pump motor speed [1/min.]:
2,830
2,642
Pump motor power input P1 [kW]:
0.7
1.5
Pump motor output P2 [kW]:
0.6
1.1
Pump motor nominal current [A]:
1.3
2.6
Maximum starts per hour:
30
30
Maximum ball through-flow [mm]:
40
50
Medium temperature range [°C]:
40
40
Fluid pH-value:
6 – 14
6 – 14
Fluid viscosity [mm²/s]:
1.005
1.005
Medium density [kg/ m³]:
1,100
1,100
Weight [kg]:
14
20