Troubleshooting flowchart
Problem releasing brakes
Check connec!on from X1
to manipulator
Repair connec!on
Connec!on not OK
Connec!on OK
Check connec!on from
T4.X15 to X1
Repair connec!on
Check connec!on from
T4.X13 to A1.X11
Connec!on OK
Connec!on not OK
Test the brake
Test the brake release
Brake is OK
Brake not OK
Repair connec!on
Not OK
Connec!on not OK
Connec!on OK
Troubleshoot
- brake release on
manipulator
- drive unit T4
- power unit A1
- computer and logic
unit A2
Problem solved
Contact ABB
Brake release is OK
xx2100001558