![ABB OmniCore E10 Скачать руководство пользователя страница 93](http://html.mh-extra.com/html/abb/omnicore-e10/omnicore-e10_product-manual_5108093.webp)
ESOUT - emergency stop output
Description
Pin
High side terminal of Emergency stop output Channel 1.
Low side terminal of Emergency stop output Channel 1.
ESOUT1-
High side terminal of Emergency stop output Channel 2.
Low side terminal of Emergency stop output Channel 2.
ESOUT2-
Note
The ESOUT pins fulfill the IEC 61131-2 Type 0,25 Output.
Note
The device connected to the ESOUT pins shall fulfill the IEC 61131-2 Type 1
Input.
If the device cannot meet the requirement, a safety PLC or relay is needed. ABB
Safety Relay E1T 1 s, 24DC is recommended.
ESOUT1
-
Safety PLC
or Relay
Relay Output for
Safety Input
of Next Stage
ESOUT2
-
Safety PLC
or Relay
Relay Output for
Safety Input
of Next Stage
Isola!on
Isola!on
K2.X15
Customer provided device
14
13
12
11
xx2000001763
Note
State 0 of Emergency stop output shall be recognized as Emergency stop
triggered.
Note
The maximum length of the cable connected to the ESOUT pins shall be 10 m.
Continues on next page
Product manual - OmniCore E10
93
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.8 Descriptions for connectors
Continued
Содержание OmniCore E10
Страница 1: ...ROBOTICS Product manual OmniCore E10 ...
Страница 2: ...Trace back information Workspace 22A version a10 Checked in 2022 03 02 Skribenta version 5 4 005 ...
Страница 8: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 198: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 224: ...This page is intentionally left blank ...
Страница 228: ......
Страница 229: ......