Required tools and equipment
Note
Article number
Equipment
Content is defined in section
Standard toolkit for controller on
page 202
.
-
Standard toolkit
-
ESD protective wrist band
Required documents
Note
Article number
Document
3HAC076810-008
Circuit diagram - OmniCore E10
Removing the manipulator signal (SMB) and motors power unit harness assembly
Preparations
Note/Illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
2
xx2100001295
Removing the controller top cover on
page 120
Remove the top cover of the controller.
3
Disconnecting the connectors to the computer and logic unit
Note/Illustration
Action
Disconnect:
•
A2.X9 - T4.X3
•
A2.X10 - T4.X1
•
A1.X6 - A2.X11
•
A1.X13 - A2.X12
•
A2.X13 - G1/G2.X1
1
Continues on next page
148
Product manual - OmniCore E10
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the manipulator signal (SMB) and motors power unit harness assembly
Continued
Содержание OmniCore E10
Страница 1: ...ROBOTICS Product manual OmniCore E10 ...
Страница 2: ...Trace back information Workspace 22A version a10 Checked in 2022 03 02 Skribenta version 5 4 005 ...
Страница 8: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 198: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 224: ...This page is intentionally left blank ...
Страница 228: ......
Страница 229: ......