Note/Illustration
Action
xx1800001193
Refit the power cable.
2
xx1800001748
Reconnect the power cable to the Flex-
Pendant.
3
Screws: Torx pan head screw M4x8 (3 pcs)
xx1800001196
Refit the power cable cover and tighten
the screws.
4
Perform the function tests to verify that
the safety features work properly, see
5
160
Product manual - OmniCore E10
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the power cable and power cable cover
Continued