4 Maintenance
4.1 Maintenance schedule, OmniCore
General
The controller must be maintained at regular intervals to ensure its function. The
activities and intervals are described in this section.
Activities and intervals
Detailed in section:
Interval
Maintenance
activity
Equipment
Inspecting the OmniCore E10 con-
troller on page 106
12 months
i
Inspection
Complete controller
Inspecting the OmniCore E10 con-
troller on page 106
6 months
Inspection
System fans
Cleaning of the controller cabinet
on page 107
Cleaning
Control cabinet
Cleaning the FlexPendant on
page 108
When needed
Cleaning
FlexPendant
Function test of emergency stop on
page 110
12 months
Function test
Emergency stop
(FlexPendant)
Function test of manual, auto, and
manual full speed mode with Flex-
Pendant on page 111
12 months
Function test
Manual, auto and
manual full speed
mode with FlexPend-
ant
Function test of three-position en-
abling device on page 112
12 months
Function test
Enable device
Function test of safety switches on
page 113
12 months
Function test
Safety switches
Function test of Automatic Stop on
page 114
12 months
Function test
Auto stop (tested if
used)
Function test of General Stop on
page 115
12 months
Function test
General stop (tested
if used)
Function test of external emergency
stop on page 116
12 months
Function test
External emergency
stop (tested if used)
Function test of ESTOP_STATUS
output on page 117
12 months
Function test
ESTOP_STATUS
output (tested if
used)
Function test of reduced speed
control on page 118
.
During commis-
sioning
Function test
Reduced speed
control
i
The interval depends on the working environment of the equipment: a cleaner environment may
extend the maintenance interval and vice versa.
Function test after replacement of component
After replacing a component in the controller, the function tests should be
performed. See
Product manual - OmniCore E10
105
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
4 Maintenance
4.1 Maintenance schedule, OmniCore
Содержание OmniCore E10
Страница 1: ...ROBOTICS Product manual OmniCore E10 ...
Страница 2: ...Trace back information Workspace 22A version a10 Checked in 2022 03 02 Skribenta version 5 4 005 ...
Страница 8: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 198: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 224: ...This page is intentionally left blank ...
Страница 228: ......
Страница 229: ......