figures for the best safety performance. When the 24 V power is provided by
customer instead of 24V_CH1/2, it shall be within the tolerance of 24 V -5%/+5%.
Customer provided power
0V_CH1_CH2
24V_CH1
0V_CH1_CH2
24V_CH2
0V_CH1_CH2
24V_CH1
0V_CH1_CH2
24V_CH2
0V_CH1_CH2
24V_CH1
0V_CH1_CH2
24V_CH2
0V_CH1_CH2
24V_CH1
0V_CH1_CH2
24V_CH2
Customer_24V_CH1
Customer_24V_CH2
Customer_0V_CH1
Customer_0V_CH2
Customer_24V_CH1
Customer_24V_CH2
Customer_0V_CH1
Customer_0V_CH2
(A)
(B)
(C)
(D)
Customer provided power
ES1+
ES1-
ES2+
ES2-
ES1+
ES1-
ES2+
ES2-
ES1+
ES1-
ES2+
ES2-
ES1+
ES1-
ES2+
ES2-
xx2100001572
Note
It is prohibited to connect the dual-channel switch as shown in the following
figure, as this does not comply with the Cat.3 structure.
0V_CH1_CH2
24V_CH1
0V_CH1_CH2
24V_CH2
0V_CH1_CH2
24V_CH1
0V_CH1_CH2
24V_CH2
(A)
(B)
ES1+
ES1-
ES2+
ES2-
ES1+
ES1-
ES2+
ES2-
xx2100001573
For more connections other than those illustrated above, carefully assess the risk
before use and contact your local ABB for support.
Continues on next page
92
Product manual - OmniCore E10
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.8 Descriptions for connectors
Continued
Содержание OmniCore E10
Страница 1: ...ROBOTICS Product manual OmniCore E10 ...
Страница 2: ...Trace back information Workspace 22A version a10 Checked in 2022 03 02 Skribenta version 5 4 005 ...
Страница 8: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 198: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 224: ...This page is intentionally left blank ...
Страница 228: ......
Страница 229: ......