6.2.2 Start-up failure
Description
The following are possible symptoms of a start-up failure:
1 The LEDs are not lit on some units.
2 Unable to load the system software.
Required test equipment
Equipment needed for troubleshooting:
Note
Equipment
Multimeter
Insulating gloves
3HAC076810-008
Circuit diagram - OmniCore E10
Preparations
Action
Make sure that the controller is switched on.
1
Wait 30 s - 1 min to enable start-up sequence.
Check the FlexPendant for errors and warnings.
2
DANGER
Troubleshooting on the controller while powered on must be performed by personnel
trained by ABB or by ABB field engineers.
Detailed working procedure
Note
Action
For more details about the LEDs,
see
Look at the computer and logic unit status LED
Computer.
1
For more details about the LEDs,
see
Troubleshooting the power unit
.
Look at the power unit status LED.
2
For more details about the LEDs,
see
Troubleshooting the drive unit
.
Look at the drive unit status LED.
3
If the problem remains, contact ABB.
4
Tip
For more details, see
Circuit diagram - OmniCore E10
.
Product manual - OmniCore E10
171
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
6 Troubleshooting
6.2.2 Start-up failure
Содержание OmniCore E10
Страница 1: ...ROBOTICS Product manual OmniCore E10 ...
Страница 2: ...Trace back information Workspace 22A version a10 Checked in 2022 03 02 Skribenta version 5 4 005 ...
Страница 8: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 198: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 224: ...This page is intentionally left blank ...
Страница 228: ......
Страница 229: ......