Note/Illustration
Action
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
2
xx2100001295
Screws: Torx pan head screw M4x8 (4 pcs)
Refit the power unit and secure with the
screws.
3
Tightening torque: 1.7 Nm±10%
xx2100001335
xx2100001334
Insert the fan connector to the bracket.
4
Continues on next page