Note/Illustration
Action
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
When handling the computer outside of
the controller, use the wrist strap button
located on the side of the computer.
2
xx2100001295
Reconnect:
•
A2.X9 - T4.X3
•
A2.X10 - T4.X1
•
A1.X6 - A2.X11
•
A1.X13 - A2.X12
•
A2.X13 - G1/G2.X1
3
Concluding procedure
Note/Illustration
Action
Refitting the controller cover on page 121
Refit the top cover.
1
Perform the function tests to verify that
the safety features work properly, see
2
152
Product manual - OmniCore E10
3HAC079399-001 Revision: C
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the manipulator signal (SMB) and motors power unit harness assembly