44 Program features
Jog cmd = State of source set by
Jog enable = State of source set by
Start cmd = State of drive start command.
Phase Jog
cmd
Jog
enable
Start
cmd Description
1-2
1
1
0
Drive accelerates to the jogging speed along the
acceleration ramp of the jogging function.
2-3
1
1
0
Drive follows the jog reference.
3-4
0
1
0
Drive decelerates to zero speed along the deceleration
ramp of the jogging function.
4-5
0
1
0
Drive is stopped.
5-6
1
1
0
Drive accelerates to the jogging speed along the
acceleration ramp of the jogging function.
6-7
1
1
0
Drive follows the jog reference.
7-8
0
1
0
Drive decelerates to zero speed along the deceleration
ramp of the jogging function.
8-9
0
1->0
0
Drive is stopped. As long as the jog enable signal is on,
start commands are ignored. After jog enable switches
off, a fresh start command is required.
9-10
x
0
1
Drive accelerates to the speed reference along the
selected acceleration ramp (parameters
10-11
x
0
1
Drive follows the speed reference.
11-12
x
0
0
Drive decelerates to zero speed along the selected
deceleration ramp (parameters
…
).
12-13
x
0
0
Drive is stopped.
13-14
x
0
1
Drive accelerates to the speed reference along the
selected acceleration ramp (parameters
2 3
1
4 5 6
8
11
13
14 15 16
t
7
18
9
12
10
17
Jog cmd
Jog enable
Start cmd
Speed
Содержание ACS280
Страница 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Страница 4: ......
Страница 10: ...10 ...
Страница 16: ...16 Control panel ...
Страница 20: ...20 Start up ID run and use ...
Страница 24: ...24 Default control connection ...
Страница 88: ...88 Program features ...
Страница 298: ...298 Parameters ...