Fieldbus control through the embedded fieldbus interface (EFB)
413
6402h 0
Motor type
U6
RO
This object indicates the type of motor
attached to and driven by the drive
device.
The following value definition is valid:
0000h = non-standard motor
0001h = phase modulated DC motor
0002h = frequency controlled DC motor
0003h = PM synchronous motor
0004h = FC synchronous motor
0005h = switched reluctance motor
0006h = wound rotor induction motor
0007h = squirrel cage induction motor
0008h = stepper motor
0009h = micro-step stepper motor
0010h = sinusoidal PM BL motor
0011h = trapezoidal PM BL motor
0012h = AC synchronous reluctance
sync
0013h = DC commutator PM
0014h = DC commutator wound field
series
0015h = DC commutator wound field
compound
7FFFh = no motor type assigned
8000h-FFFFh = manufacturer-specific