286 Parameters
98
Motor values supplied by the user that are used in the
motor model.
These parameters are useful for non-standard
motors, or to just get more accurate motor control of
the motor on site. A better motor model always
improves the shaft performance.
Activates the motor model parameters
and
.
Notes
:
• Parameter value is automatically set to zero when
ID run is selected by parameter
are then updated according to the motor
characteristics identified during the ID run.
• Measurements made directly from the motor
terminals during the ID run are likely to produce
slightly different values than those on a data sheet
from a motor manufacturer.
• This parameter cannot be changed while the drive
is running.
not used
inactive.
0
Motor parameters
The values of parameters
are used as
the motor model.
1
Defines the stator resistance
R
S
of the motor model.
With a star-connected motor,
R
S
is the resistance of
one winding. With a delta-connected motor,
R
S
is one-
third of the resistance of one winding.
0.00000 p.u.
0.00000…0.50000 p.u.
Stator resistance in per unit.
-
Defines the rotor resistance
R
R
of the motor model.
Note:
This parameter is valid only for asynchronous
motors.
0.00000 p.u.
0.00000…0.50000 p.u.
Rotor resistance in per unit.
-
Defines the main inductance
L
M
of the motor model.
Note:
This parameter is valid only for asynchronous
motors.
0.00000 p.u.
0.00000… 10.00000
p.u.
Main inductance in per unit.
-
Defines the leakage inductance
L
S
.
Note:
This parameter is valid only for asynchronous
motors.
0.00000 p.u.
0.00000…1.00000 p.u.
Leakage inductance in per unit.
-
Defines the direct axis (synchronous) inductance.
Note:
This parameter is valid only for permanent
magnet motors.
0.00000 p.u.
0.00000 … 10.00000
p.u
Direct axis inductance in per unit.
-
Defines the quadrature axis (synchronous)
inductance.
Note:
This parameter is valid only for permanent
magnet motors.
0.00000 p.u.
No.
Name/Value
Description
Default
FbEq 16
Содержание ACS280
Страница 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Страница 4: ......
Страница 10: ...10 ...
Страница 16: ...16 Control panel ...
Страница 20: ...20 Start up ID run and use ...
Страница 24: ...24 Default control connection ...
Страница 88: ...88 Program features ...
Страница 298: ...298 Parameters ...