Additional parameter data 325
97.15 Motor model temperature
adaptation
0...1
-
1 = 1
97.16 Stator temperature factor
0...200
%
1=1%
97.17 Rotor temperature factor
0...200
%
1=1%
97.20 U/f ratio
0…1
-
1 = 1
97.33 Speed estimate filter time
0.00...100.00
-
1 = 1
97.35
Automatic LS mode
-
97.36
LS mode activation speed
0.00...100.00
%
0.0
97.48 Udc stabilizer
0, 50, 100, 300, 500, 800 %
1 = 1%
97.49 Slip gain for scalar
0...200
%
1 = 1%
97.94 IR comp max frequency
1.0...200.0
%
10 = 1%
97.135 Udc ripple
0.0...200.0
V
10 = 1V
98 User motor parameters
98.01 User motor model mode
0…1
-
1 = 1
98.02 Rs user
0.0000…0.50000
p.u.
100000 = 1
p.u.
98.03 Rr user
0.0000…0.50000
p.u.
100000 = 1
p.u.
98.04 Lm user
0.00000…10.00000
p.u.
100000 = 1
p.u.
98.05 SigmaL user
0.00000…1.00000
p.u.
100000 = 1
p.u.
98.06 Ld user
0.00000…10.00000
p.u.
100000 = 1
p.u.
98.07 Lq user
0.00000…10.00000
p.u.
100000 = 1
p.u.
98.08 PM flux user
0.00000…2.00000
p.u.
100000 = 1
p.u.
98.09 Rs user SI
0.00000…100.00000
ohm
100000 = 1
p.u.
98.10 Rr user SI
0.00000…100.00000
ohm
100000 = 1
p.u.
98.11 Lm user SI
0.00…100000.00
mH
100 = 1 mH
98.12 SigmaL user SI
0.00…100000.00
mH
100 = 1 mH
98.13 Ld user SI
0.00…100000.00
mH
100 = 1 mH
98.14 Lq user SI
0.00…100000.00
mH
100 = 1 mH
99 Motor data
99.03 Motor type
0…1
-
1 = 1
99.04 Motor control mode
0…1
-
1 = 1
99.06 Motor nominal current
0.0…6400.0
A
See P
99.07 Motor nominal voltage
0.0…800.0
V
See P
99.08 Motor nominal frequency
0.00 … 500.00
Hz
100 = 1 Hz
99.09 Motor nominal speed
0 … 30000
rpm
1 = 1 rpm
No.
Name
Type
Range
Unit
FbEq32
Содержание ACS280
Страница 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Страница 4: ......
Страница 10: ...10 ...
Страница 16: ...16 Control panel ...
Страница 20: ...20 Start up ID run and use ...
Страница 24: ...24 Default control connection ...
Страница 88: ...88 Program features ...
Страница 298: ...298 Parameters ...