Parameters 123
AO has automatic scaling. Every time the source for the AO is changed, the scaling range is
changed accordingly. User given minimum and maximum values override the automatic
values.
-32768.0…32767.0
Real signal value corresponding to minimum AO1
output value.
1 = 1
Defines the real maximum value of the signal
) that
corresponds to the maximum required AO1 output
value (defined by parameter
). See parameter
.
50.0
-32768.0…32767.0
Real signal value corresponding to maximum AO1
output value.
1 = 1
Defines the minimum output value for analog output
AO1.
See also drawing at parameter
0.000 V
0.000…11.000 V
Minimum AO1 output value.
1000 = 1 V
Defines the maximum output value for analog output
AO1.
See also drawing at parameter
.
10V
0.000…11.000 V
Maximum AO1 output value.
1000 = 1 V
No.
Name/Value
Description
Default
FbEq 16
13.12
AO1 source
13.17
AO1 source min
13.18
AO1 source max
0
Zero
N/A (Output is constant zero.)
1
Motor speed used
0
46.01
Speed scaling
3
Output frequency
0
46.02
Frequency scaling
4
Motor current
0
Max. value of
30.17
Maximum current
5
Motor current % of motor
nom
0%
100%
6
Motor torque
0
46.03
Torque scaling
7
DC voltage
Min. value of
01.11
DC
voltage
Max. value of
01.11
DC
voltage
8
Output power
0
46.04
Power scaling
10
Speed ref ramp in
0
46.01
Speed scaling
11
Speed ref ramp out
0
46.01
Speed scaling
12
Speed ref used
0
46.01
Speed scaling
14
Freq ref used
0
46.02
Frequency scaling
16
Process PID out
Min. value of
40.01
Process
PID output actual
Max. value of
40.01
Process
PID output actual
20
Temp sensor 1 excitation
N/A (Analog output is not scaled; it is determined by the
sensor’s triggering voltage.)
26
Abs motor speed used
0
46.01
Speed scaling
27
Abs motor speed %
0
46.01
Speed scaling
28
Abs output frequency
0
46.02
Frequency scaling
30
Abs motor torque
0
46.03
Torque scaling
31
Abs output power
0
46.04
Power scaling
32
Abs motor shaft power
0
46.04
Power scaling
Other
Min. value of the selected
parameter
Max. value of the selected
parameter
Содержание ACS280
Страница 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Страница 4: ......
Страница 10: ...10 ...
Страница 16: ...16 Control panel ...
Страница 20: ...20 Start up ID run and use ...
Страница 24: ...24 Default control connection ...
Страница 88: ...88 Program features ...
Страница 298: ...298 Parameters ...