VES-1000 Series Ethernet Switch
26-4
Troubleshooting
Table 26-9 Troubleshooting Connecting to the WAN Switch
STEPS CORRECTIVE
ACTION
1
Check your cable connections. Use a straight through Ethernet cable when connecting the VES to a WAN
switch. Use a crossover Ethernet cable if you are daisy-chaining to other VES-1000 Series switches and
make sure trunking is disabled.
2
If Ethernet port trunking is enabled (in SMT menu 2), make sure the WAN switch also supports Ethernet port
trunking.
3
The factory default settings for the Ethernet port of the VES are:
Speed: Auto
Duplex: Auto
Flow control: On
Trunking: Disabled
If the VES’s auto-negotiation is turned off, an Ethernet port uses the pre-configured speed and duplex mode
when making a connection, thus requiring you to make sure that the settings of the WAN switch Ethernet
port are in the same order to connect.