
VES-1000 Series Ethernet Switch
VLAN Setup
18-3
Table 18-2 Menu 17.1.1 – 802.1Q VLAN Static Entry Setup
FIELD
DESCRIPTION
Port01 ~ Port14
Press [SPACE BAR] to choose from
Fixed-U
,
Fixed-T
,
Forbidden
,
Normal-U
or
Normal-
T
. The abbreviations are defined as follows.
Fixed-U
Fixed Regist Untagged
Fixed-T
Fixed Regist Tagged
Forbidden
Forbidden Registration
Normal-U
Normal Regist Untagged
Normal-T
Normal Regist Tagged
Trunk
Press [SPACE BAR] to choose from
Fixed-U
,
Fixed-T
,
Forbidden
,
Normal-U
or
Normal-
T
. This field is available only when you enable Ethernet ports (VES-1008A Ethernet ports 8
and 9 are equivalent to Ethernet ports 13 and 14 in the VES-1012) trunking in
Menu 2 -
Switch Setup
.
Once you have completed filling in
Menu 17.1.1 — 802.1Q VLAN Static Entry Setup
, press [ENTER] at the
message “Press ENTER to Confirm… “ to save your configuration or press [ESC] at any time to cancel.
Tagged and Untagged governs the outgoing frames. Fixed/forbidden/normal governs VLAN registration.
Note that care must be taken when configuring VLAN for the management port; if the configuration is not correct,
it will render the VES unreachable from the remote management station. The following are guidelines for tagged
VLAN configuration:
•
Reserve one VID specifically for management purpose. Assign that VID to be the management VLAND ID.
•
Make sure the member set of the management VID includes the uplink port through which the management
station talks to the VES. If you don’t know which uplink port it is, include both uplink ports in the member
set of the management VID. It generally does no harm in doing this, since typically both uplink ports talk to
each other already.
•
Save the configuration only after you configure both the management VLAN ID and the member set of that
VID consistently. Otherwise, the VES will be unreachable in-band through the uplink ports, since the traffic
will be blocked by the inconsistent VLAN setting.
•
PC and Workstations generally do not support tagged VLAN. If the management station indeed does not
support tagged VLAN, you must connect it to a VLAN-aware switch and configure the PVID of the port
connected to the management station to be the management VID.
18.3 Port-Based VLAN Setup
Port-based VLANs are VLANs where the packet forwarding decision is based on the destination MAC address
and its associated port.
Summary of Contents for VES-1000 Series
Page 1: ...VES 1000 Series VDSL Ethernet Switches Version 3 41 May 2004 User s Guide...
Page 20: ......
Page 32: ......
Page 50: ......
Page 64: ......
Page 72: ......
Page 74: ......
Page 78: ......
Page 100: ......
Page 104: ......
Page 106: ......
Page 112: ......
Page 120: ......
Page 128: ......
Page 130: ......
Page 142: ......
Page 176: ......
Page 178: ......
Page 206: ......
Page 210: ......
Page 216: ......