Table 22-5 Menu 24.12 - Hardware Monitor
FIELD DESCRIPTION
EXAMPLE
Current
This is the current voltage reading.
2.03
Max
This field displays the maximum voltage measured at this point.
Min
This field displays the minimum voltage measured at this point.
Tolerance (%)
Five percent is the acceptable deviation from the nominal voltage.
5%
Status
“Normal” indicates that the voltage is within an acceptable operating range at
this point.
Normal
COMMANDS:
r-Reset status
Enter “r” to refresh all the counters in this menu.
r
ESC-exit
Press [ESC] to exit this menu and return to SMT menu 24.
[ESC]
If an error is detected:
The associated
Status
field in
Menu 24.12 — Hardware Monitor
will display
Error
.
The ALM (alarm) LED on the front panel will light.
To clear an alarm, enter “r” in
Menu 24.12 — Hardware Monitor
.
22.5 Return to Default Setting
Enter 14 from
Menu 24 – System Maintenance
to go to the next menu shown. Enter
y
and press [ENTER] to have
the VES reboot. This will reset the VES to the factory defaults as shown in the menu.
Figure 22-7 Menu 24.14 - Return to Default Setting
Default Romfile reset...
System Restart(Console speed will be changed to 9600 bps)
IP will be changed to 192.168.1.1
IP mask will be changed to 255.255.255.0
All previous setting will be set to the default value.
Would you like to proceed?(y/n)
Summary of Contents for VES-1000 Series
Page 1: ...VES 1000 Series VDSL Ethernet Switches Version 3 41 May 2004 User s Guide...
Page 20: ......
Page 32: ......
Page 50: ......
Page 64: ......
Page 72: ......
Page 74: ......
Page 78: ......
Page 100: ......
Page 104: ......
Page 106: ......
Page 112: ......
Page 120: ......
Page 128: ......
Page 130: ......
Page 142: ......
Page 176: ......
Page 178: ......
Page 206: ......
Page 210: ......
Page 216: ......