If you have not licensed HFA-NET Pro, and WORK LIST has not been enabled on the DICOM
Gateway Services screen, a message is displayed as shown in
. You need to enable
WORK LIST to use the DICOM Gateway 2.0 worklist function (see
Gateway Services:" on page H-4
).
Figure 14.57 Work List is Not Available Message
4
You can limit the selection by Accession Number, Last Name, First Name, Patient ID, and
Requested Procedure ID (
). These query fields are case independent. Specify any
limitations that you wish to place on your search of all available patients from the Work List.
Select the CLEAR QUERY button to clear all these query fields. These limitations along with the
entries on the Work List Broad Query Setup screen (
) determine which patient(s)
are selected.
Note: Accession Number and Requested Procedure ID are identifying numbers for exams or
procedures. See your EMR/PMS/DICOM documentation for more information.
Note: If your DICOM system supports the wild card character “*”, you can enter it to mean any
characters in the Last Name and First Name fields. For example, entering “j*” in the First Name field
would select all patients with a first name starting with “j”. Entering “*” in the Last Name field and
leaving the First Name and Patient ID fields blank would select all patients from the DICOM Archive.
Note: In order to be able to see the correct list of patients, you must ensure that the scheduled
patient date on the DICOM server matches the local system date on the HFA.
5
Select the BROAD QUERY SETUP button to display the Work List Broad Query Setup screen.
Initially, all fields are blank and all patients from the Work List will be selected. When the
DEFAULT button is selected (
) the values are set to select patients from the work
list for today (HFA system date), to the AE Title entered in the DICOM Gateway Setup screen
(see
“DICOM 2.0 Gateway Setup on HFA,” on page H-3
), and to the OPV modality type code
(Ophthalmic Visual Field). Broad Query is useful to obtain a list of all patients scheduled
regardless of instrument, or to see the entire worklist irrespective of the date scheduled.
Summary of Contents for Humphrey II-i series
Page 1: ...User Manual Humphrey Field Analyzer II i series System Software Version 5 1...
Page 8: ...Humphrey Field Analyzer II i series User Manual 2660021145640 A vi...
Page 74: ...General Operation Humphrey Field Analyzer II i series User Manual 2660021145640 A 2 34...
Page 130: ...Testing Humphrey Field Analyzer II i series User Manual 2660021145640 A 5 20...
Page 158: ...STATPAC Analysis Printing Humphrey Field Analyzer II i series User Manual 2660021145640 A 7 22...
Page 338: ...Kinetic Testing Humphrey Field Analyzer II i series User Manual 2660021145640 A 13 62...
Page 412: ...Care and Cleaning Humphrey Field Analyzer II i series User Manual 2660021145640 A 15 14...
Page 416: ...Product Specifications Humphrey Field Analyzer II i series User Manual 2660021145640 A A 4...
Page 420: ...Product Features Humphrey Field Analyzer II i series User Manual 2660021145640 A B 4...
Page 428: ...Icon Glossary Humphrey Field Analyzer II i series User Manual 2660021145640 A D 2...
Page 579: ......