INSTRUMENT DESCRIPTION
Carl Zeiss
Technical Data
Axiovert 200
1-14
B 40-080 e 03/01
1.9
Technical Data
Dimensions (width x depth x height)
Stand Axiovert 200.................................................................................... approx. 295
×
805
×
707 mm
Weight
Axiovert 200 without fluorescence equipment ................................................................... approx. 26 kg
Axiovert 200 M with fluorescence equipment .................................................................... approx. 40 kg
Ambient conditions
Storage and transport (in packaging):
Permissible ambient temperature................................................................................... -40 to +50 °C
Operation:
Permissible ambient temperature.................................................................................. +10 to +35 °C
Permissible relative humidity (without condensation)...........................................................max. 80 %
Altitude of use ............................................................................................................... max. 2000 m
Atmospheric pressure......................................................................................... 800 hPa to 1060 hPa
Pollution degree............................................................................................................................... 2
Operating data
Category of use.................................................................................................................. closed rooms
Protection class.......................................................................................................................................I
Protection type ................................................................................................................................ IP 20
Electrical safety.................................................................in compliance with DIN EN 61010 (IEC 1010-1)
...............................................................................................................
including CSA and UL directives
Excess voltage category .........................................................................................................................II
Radio interference suppression....................................................... in accordance with EN 55011, Class B
Voltage ranges:
Integrated 12 V, 100 W power unit, stabilized ............................................ 100 to 240 VAC (
±
10 %)
Summary of Contents for Axiovert 200
Page 1: ...Operating Manual Axiovert 200 Axiovert 200 M Inverted Microscopes...
Page 30: ...INSTRUMENT DESCRIPTION Carl Zeiss Technical Data Axiovert 200 1 16 B 40 080 e 03 01...
Page 34: ...START UP Carl Zeiss List of illustrations Axiovert 200 2 4 B 40 080 e 03 01...
Page 114: ...ANNEX Carl Zeiss Overview Axiovert 200 A 2 B 40 080 e 03 01...
Page 120: ...ANNEX Carl Zeiss List of key words Axiovert 200 A 8 B 40 080 e 03 01...