1.5 Defaults by Drive Model Selection (o2-04)
92
YASKAWA ELECTRIC
TOEP C710687 03B FSDrive-MV1000 Parameter Guide
Table 1.8 11 kV Class Drives Default Settings by Drive Model Selection
No.
Name
Unit
Default Settings
–
Model
CIMR-MV2
–
035
050
070
100
140
200
260
330
400
520
650
o2-04
Drive Model
Selection
–
80
81
82
83
84
85
86
87
88
89
8A
E2-11 (E4-11)
<61> Parameter numbers shown in parenthesis are valid for motor 2.
<62> The alarm detection level differs for each drive model because of the different thermistor position on each drive.
Motor Rated Power kW
530
760
1070
1520
2130
3050
3960
5030
6100
7930
9910
b3-04
V/f Gain during Speed
Search
%
80
80
80
80
80
80
80
80
80
80
80
b3-06
Output Current 1 during
Speed Search
–
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
b3-11
Speed Search Method
Switching Level (Speed
Estimate Type Speed
Search)
%
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
E2-01 (E4-01) Motor Rated Current
A
30.0
45.0
60.0
85.0
120.0
170.0
220.0
280.0
340.0
440.0
550.0
E2-02 (E4-02) Motor Rated Slip
Hz
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
E2-03 (E4-03) Motor No-Load Current A
8.0
11.0
15.0
21.0
30.0
43.0
55.0
70.0
85.0
110.0
138.0
E2-05 (E4-05)
Motor Line-to-Line
Resistance
W
0.300
0.300
0.300
0.300
0.300
0.300
0.300
0.300
0.300
0.300
0.300
E2-06 (E4-06)
Motor Leakage
Inductance
%
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
E2-10 (E4-10)
Motor Iron Loss for
Torque Compensation
W
0
0
0
0
0
0
0
0
0
0
0
L2-02
Momentary Power Loss
Ride-Thru Time
s
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
L2-03
Momentary Power Loss
Ride-Thru Minimum
Baseblock Time
s
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
L2-04
Momentary Power Loss
Ride-Thru Voltage
Recovery Time
s
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
L2-05
Undervoltage Detection
Level (Uv)
V
1188 1188 1188 1188 1188 1188 1188 1188 1188 1188 1188
Overheat Alarm Level
–
105
105
105
105
105
105
95
105
105
100
105
L8-09
Output Ground Fault
Detection Selection
–
1
1
1
1
1
1
1
1
1
1
1
L8-33
FAN Board Use
Selection
–
2
2
2
2
2
2
2
2
2
2
2
L8-87
Transformer Overheat
Alarm (TMA) Level
°
C
130
130
130
130
130
130
130
130
130
130
130
L8-88
Transformer Overheat
Fault (TME) Level
°
C
140
140
140
140
140
140
140
140
140
140
140
n1-03
Hunting Prevention
Time Constant
ms
30
30
30
30
30
30
30
30
30
30
30
n9-02
Output Current
Detection Gain
–
100
100
1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000
n9-71
Input Current
Conversion Coefficient
–
0.0340 0.0340 0.0235 0.0150 0.0110 0.0094 0.0060 0.0060 0.0040 0.0040 0.0030
o2-11
Reference Voltage for
Input Voltage Detection
V
11000
11000
11000
11000
11000
11000
11000
11000
11000
11000
11000