1.3 Parameter Table
46
YASKAWA ELECTRIC
TOEP C710687 03B FSDrive-MV1000 Parameter Guide
F6-08
(36AH)
Reset
Communication
Parameters
0: Host controller-related parameters (F6-
/F7-
) are not reset when
the drive is initialized using A1-03.
1: Reset all host controller-related parameters (F6-
/F7-
) when the
drive is initialized using A1-03.
Default: 0
Min: 0
Max: 1
F6-30
(3CBH)
PROFIBUS-DP
Node Address
Sets the node address.
Default: 0
Min: 0
Max: 125
–
F6-31
(3CCH)
PROFIBUS-DP
Clear Mode
Selection
0: Resets drive operation with a Clear Mode command.
1: Maintains the previous operation state when Clear Mode command is
given.
Default: 0
Min: 0
Max: 1
–
F6-32
(3CDH)
PROFIBUS-DP
Data Format
Selection
0: PPO Type
1: Mode for compatibility with previous products
Default: 0
Min: 0
Max: 1
–
F6-50
(3C1H)
DeviceNet MAC
Address
Sets the MAC address.
Default: 0
Min: 0
Max: 64
–
F6-51
(3C2H)
DeviceNet
Communications
Speed
0: 125 kbps
1: 250 kbps
2: 500 kbps
3: Adjustable from network
4: Detect automatically
Default: 0
Min: 0
Max: 4
–
F6-52
(3C3H)
DeviceNet PCA
Setting
Sets the format of the data set from the DeviceNet master to the drive.
Default: 21
Min: 0
Max: 255
–
F6-53
(3C4H)
DeviceNet PPA
Setting
Sets the format of the data set from the drive to the DeviceNet master.
Default: 71
Min: 0
Max: 255
–
F6-54
(3C5H)
DeviceNet Idle
Mode Fault
Detection
0: Enabled
1: Disabled, no fault detection
Default: 0
Min: 0
Max: 1
–
F6-55
(3C6H)
DeviceNet Baud
Rate Monitor
Verifies the baud rate running on the network.
0: 125 kbps
1: 250 kbps
2: 500 kbps
Default: 0
Min: 0
Max: 2
–
F6-56
(3D7H)
DeviceNet Speed
Scaling
Sets the scaling factor for the speed monitor in DeviceNet.
Default: 0
Min: -15
Max: 15
–
F6-57
(3D8H)
DeviceNet Current
Scaling
Sets the scaling factor for the output current monitor in DeviceNet.
Default: 0
Min: -15
Max: 15
–
F6-58
(3D9H)
DeviceNet Torque
Scaling
Sets the scaling factor for the torque monitor in DeviceNet.
Default: 0
Min: -15
Max: 15
–
F6-59
(3DAH)
DeviceNet Power
Scaling
Sets the scaling factor for the power monitor in DeviceNet.
Default: 0
Min: -15
Max: 15
–
F6-60
(3DBH)
DeviceNet Voltage
Scaling
Sets the scaling factor for the voltage monitor in DeviceNet.
Default: 0
Min: -15
Max: 15
–
F6-61
(3DCH)
DeviceNet Time
Scaling
Sets the scaling factor for the time monitor in DeviceNet.
Default: 0
Min: -15
Max: 15
–
No.
(Addr.)
Name
Description
Setting
Page
All Modes
common_
All Modes
common_
All Modes
common_
All Modes
common_
All Modes
common_
All Modes
common_
All Modes
common_
All Modes
common_
All Modes
common_
All Modes
common_
All Modes
common_
All Modes
common_
All Modes
common_
All Modes
common_
All Modes
common_
All Modes
common_
MV1000ParameterGuide_E_conditional.book 46 ページ 2013年10月11日 金曜日 午後8時18分