1.5 Defaults by Drive Model Selection (o2-04)
88
YASKAWA ELECTRIC
TOEP C710687 03B FSDrive-MV1000 Parameter Guide
Table 1.5 3 kV Class Drives Default Settings by Drive Model Selection
L8-87
Transformer
Overheat Alarm
(TMA) Level
°
C
130
130
130
130
130
130
130
130
130
130
130
130
130
130
130
130
130
130
L8-88
Transformer
Overheat Fault
(TME) Level
°
C
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
n1-03
Hunting
Prevention Time
Constant
ms
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
n9-02
Output Current
Detection Gain
–
1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000
n9-71
Input Current
Conversion
Coefficient
–
0.0235 0.0235 0.0150 0.0150 0.0150 0.0110 0.0110 0.0094 0.0094 0.0094 0.0060 0.0060 0.0060 0.0040 0.0040 0.0040 0.0030 0.0030
o2-11
Reference
Voltage for Input
Voltage Detection
V
2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400
2400
2400
2400
2400
2400
2400
<61> Parameter numbers shown in parenthesis are valid for motor 2.
<62> The alarm detection level differs for each drive model because of the different thermistor position on each drive.
Name
Unit
Default Settings
–
Model
CIMR-MV2
–
035
050
070
100
140
200
260
330
400
520
650
o2-04
Drive Model Selection –
20
21
22
23
24
25
26
27
28
29
2A
E2-11 (E4-11) Motor Rated Power
kW
160
230
320
460
640
910
1190
1510
1830
2380
2970
b3-04
V/f Gain during Speed
Search
%
80
80
80
80
80
80
80
80
80
80
80
b3-06
Output Current 1 during
Speed Search
–
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
b3-11
Speed Search Method
Switching Level (Speed
Estimate Type Speed
Search)
%
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
E2-01 (E4-01) Motor Rated Current
A
30.0
45.0
60.0
85.0
120.0
170.0
220.0
280.0
340.0
440.0
550.0
E2-02 (E4-02) Motor Rated Slip
Hz
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
E2-03 (E4-03) Motor No-Load Current
A
8.0
11.0
15.0
21.0
30.0
43.0
55.0
70.0
85.0
110.0
138.0
E2-05 (E4-05)
Motor Line-to-Line
Resistance
W
0.300
0.300
0.300
0.300
0.300
0.300
0.300
0.300
0.300
0.300
0.300
E2-06 (E4-06)
Motor Leakage
Inductance
%
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
E2-10 (E4-10)
Motor Iron Loss for
Torque Compensation
W
0
0
0
0
0
0
0
0
0
0
0
L2-02
Momentary Power Loss
Ride-Thru Time
s
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
L2-03
Momentary Power Loss
Ride-Thru Minimum
Baseblock Time
s
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
L2-04
Momentary Power Loss
Ride-Thru Voltage
Recovery Time
s
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
L2-05
Undervoltage Detection
Level (Uv)
V
940 940 940 940 940 940 940 940 940 940 940
L8-02
Overheat Alarm Level
–
105
105
105
105
105
105
95
105
105
100
105
No.
<61>
Name
Unit
Default Settings
–
Model
CIMR-
MV2
–
052 068 080 093 102 115 135 160 180 205 220
280
330
390
440
505
550
600
o2-04
Drive Model
Selection
–
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
E2-11
(E4-11)
Motor Rated
Power
kW
(HP)
170
(228)
190
(255)
260
(349)
310
(416)
340
(456)
380
(509)
450
(603)
530
(710)
600
(804)
680
(912)
730
(979)
930
(1247)
1100
(1475)
1300
(1743)
1460
(1957)
1680
(2252)
1830
(2453)
2000
(2681)
MV1000ParameterGuide_E_conditional.book 88 ページ 2013年10月11日 金曜日 午後8時18分