3 Specifications and External Dimensions for Motors
3.1.2 Ratings and Specifications
3-4
(2) Winding Selection Motor
∗
1.
The 50% ED rating (S3) is for a 10 minute cycle consisting of 5 minutes of operation and 5 minutes stopped.
∗
2.
Available only for three-phase, 200 VAC models.
Item
Model: UAKBJ-
C (200 V), -
C
E (400 V)
06
08
11
15
19
22
30
*2
50% ED Rating (S3)
*1
kW
5.5
7.5
11
15
18.5
22
30
Continuous Rating (S1)
kW
3.7
5.5
7.5
11
15
18.5
20
Continuous Rated Torque
N
x
m
71
105
143
263
249
307
332
Base Speed
min
-1
500
400
575
Maximum Speed
min
-1
7000
6000
5000
Moment of Inertia
×
10
-3
kg
x
m
2
69.0
69.0
89.0
231.0
231.0
266.0
398.0
Vibration
V5
V10
Noise
dB (A)
75 or less
80 or less
Cooling Method
Totally enclosed, external fan cooled
Protection Class
IP44 (IEC34-5)
Cooling Fan Motor
Equipped with thermostat (automatic reset)
200 V class: Three-phase 200 V 50/60 Hz, 220 V 50/60 Hz, 230 V
60 Hz
400 V class: Three-phase 400 V 50/60 Hz, 440 V 50/60 Hz, 460 V
60 Hz
Encoder (Magnetic)
Pulse encoder (1024 p/r) (standard)
Serial encoder (17-bit)
Overheating Protection
NTC thermistor
Installation
Flange type: IM B5, IM V1 (output shaft from horizontal to vertically
down)
Foot-mounted type: IM B3 (installed on floor)
Overload Capacity
200% of continuous rated (S1) output for 10 s
Thermal Class
F
Withstand Voltage
200 V class: 1500 VAC for one minute
400 V class: 1800 VAC for one minute
Insulation Resistance
500 V DC 10 M
Ω
min.
Ambient Temperature and Ambient Humidity
0 to 40
°
C, 95% RH or less (no condensation)
Altitude
1000 m or less
Bearing Lubrication
Grease
Paint Color
Munsell N1.5
Compliant Standards
JIS, JEC
Applicable
SERVOPACK
CACR-JU
Three-phase, 200 VAC
028A
036A
065A
065A
084A
102A
125A
Three-phase, 400 VAC
014D
018D
033D
033D
042D
051D
–