2 Compatible Devices
2.3.4 AC Reactor
2-22
2.3.4
AC Reactor
Make sure to install an AC reactor, which corresponds to the capacity of the individual power regeneration
converter, to each power regeneration converter.
Do not connect any equipment other than the power regeneration converter to the secondary side of the AC
reactor. If this caution is not observed, an overcurrent may occur in the power regeneration converter. An AC
reactor is effective in improving the power factor of the power supply side.
Select an AC reactor based on the following table. For details, refer to
5.2 AC Reactor
.
∗
This AC reactor does not comply with UL standards. If an AC reactor that complies with UL standards is required,
contact your Yaskawa representative.
2.3.5
Magnetic Contactor for Winding Selection
A magnetic contactor for winding selection is needed only if a winding selection motor is used as the spindle
motor.
Select a magnetic contactor for winding selection based on the following table. For details, refer to
5.3 Mag-
netic Contactor for Winding Selection
.
Power Regeneration Converter
AC Reactor Model
Input Voltage
Model
Three-phase,
200 VAC
CACP-JU15A3
X008017
CACP-JU19A3
X008018
CACP-JU22A3
X008019
CACP-JU30A3
X008020
CACP-JU45A3B
X008022
Three-phase,
400 VAC
CACP-JU15D3
X008010
*
CACP-JU19D3
X008011
CACP-JU22D3
X008012
SERVOPACK for One Axis
Magnetic Contactor
for Winding Selection
Input Voltage
Model
Model
Standard
For UL Compliance
270 VDC
CACR-JU028ACA
HV-75AP4
HV-75AP4/UL
CACR-JU036ACA
CACR-JU065ACA
540 VDC
CACR-JU014DCA
CACR-JU018DCA
CACR-JU033DCA
270 VDC
CACR-JU084ACA
HV-150AP4
HV-150AP4/UL
CACR-JU102ACA
CACR-JU125ACA
540 VDC
CACR-JU042DCA
CACR-JU051DCA