4 Specifications and External Dimensions for
Σ
-V-SD Drivers
4.1.2 External Dimensions
4-4
4.1.2
External Dimensions
(1) Model: CACP-JU15
3
, -JU19
3
, -JU22
3
∗
The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink.
(2) Model: CACP-JU30A3
∗
The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink.
Note: Available only for three-phase 200 VAC models.
380
Model Number
Input Voltage
Nameplate
7.5
(10)
80
100
10
4-6 Dia.
Ground Terminal
2-M5 Screws
(145)
300
200
Cooling Fan
4-M5 Screw Holes
Power
Regeneration
Converter
Rear View
Through
Hole
338
365
±
0.5
80
±
(Mounting Pitch)
380
10
5
90
100
Mounting Hole Diagram
(Mounting Pitch)
7.5
365
15.5
7.5
5
(100)
23
86
7
(7)
334
(23)
∗
∗
Air Flow
Air Flow
(115
°
)
Unit: mm
Approx. Mass: 8.3 kg
(145)
300
200
Cooling Fan
Heat Sink
5
(100)
23
334
(23)
∗
∗
Air Flow
Air Flow
(115
°
)
136
7
(7)
Unit: mm
Approx. Mass: 11.1 kg
380
Model Number
Input Voltage
7.5
(10)
130
150
10
4-6 Dia.
Ground Terminal
2-M6 Screws
7.5
365
Nameplate
Power
Regeneration
Converter
Rear View
4-M5 Screw Holes
(Mounting Pitch)
380
338
365
±
0.5
Through
Hole
130
±
0.5
10
5
140
150
Mounting Hole Diagram
(Mounting Pitch)
15.5 7.5