![YASKAWA CACP-JU series User Manual Download Page 321](http://html.mh-extra.com/html/yaskawa/cacp-ju-series/cacp-ju-series_user-manual_907660321.webp)
12.1 SERVOPACK Parameters
12-21
Appendix
2
1
Pn50A
(2110h:1)
2
Input Signal Selection 1
0000 to FFF1
−
1881
After restart
Setup
spindle
motor,
servo-
motor
−
Pn50B
(2110h:2)
2
Input Signal Selection 2
0000 to FFFF
−
8882
After restart
Setup
spindle
motor,
servo-
motor
–
(cont’d)
Parameter
No.
(Index No.)
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Motor
Type
Reference
Section
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
0 to 7
8
9 to F
Forward run allowed when P-OT input signal is ON (L-level)
Forward run allowed
Forward run allowed when P-OT input signal is OFF (H-level)
P-OT Signal Mapping
Reference
Section
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
7.2.5
N-OT Signal Mapping
Reference
Section
0 to 7
Reverse run allowed when N-OT input signal is ON (L-level).
7.2.5
8
Reverse run allowed.
9 to F
Reverse run allowed when N-OT input signal is OFF (H-level).
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.