12.2 Parameter Recording Table
12-31
Appendix
2
1
Pn528
2103h:2
100
Excessive Position Error
Warning Level at Servo ON
Immediately
Pn529
2103h:3
10000
Speed Limit Level at Servo
ON
Immediately
Pn52A
2102h:6
20
Multiplier per One Fully-
closed Rotation
Immediately
Pn52B
2104h:1
20
Overload Warning Level
Immediately
Pn52C
2104h:2
100
Derating of Base Current at
Detecting Overload of Motor
After restart
Pn530
2142h:1
0000
Program JOG Operation
Related Switch
Immediately
Pn531
2142h:2
32768
Program JOG Movement Dis-
tance
Immediately
Pn533
2142h:3
500
Program JOG Movement
Speed
Immediately
Pn534
2142h:4
100
Program JOG Acceleration/
Deceleration Time
Immediately
Pn535
2142h:5
100
Program JOG Waiting Time
Immediately
Pn536
2142h:6
1
Number of Times of Program
JOG Movement
Immediately
Pn541
2098h:1
65535
Rated Speed Setting
After restart
Pn542
2098h:2
15
Speed Coincidence Detection
Width
Immediately
Pn543
2098h:3
1000
Speed Detection Level
Immediately
Pn544
2098h:4
100
Speed Detection Hysteresis
Immediately
Pn545
2098h:5
0000
Speed Error Excessive Protec-
tion Select Switch
Immediately
Pn550
2116h:1
0
Analog Monitor 1 Offset Volt-
age
Immediately
Pn551
2116h:2
0
Analog Monitor 2 Offset Volt-
age
Immediately
Pn552
2116h:3
100
Analog Monitor Magnifica-
tion (
×
1)
Immediately
Pn553
2116h:4
100
Analog Monitor Magnifica-
tion (
×
2)
Immediately
Pn561
2148h
50
Overshoot Detection Level
Immediately
Pn601
2114h
0
DB Resistor Capacity
After restart
Pn630
2118h:1
0
Emergency Stop
Execution Delay Time
Immediately
Pn631
2118h:2
0
External Magnetic Contactor
OFF Delay Time
After restart
(cont’d)
Parameter
Index
Number
Factory
Setting
Name
When
Enabled