5 Peripheral Devices
5.5.1 Specifications
5-16
5.5
Base Mounting Units
When mounting servo drivers to bases, use the following base mounting units.
5.5.1
Specifications
Note: The input current that is given above is the current for one base mounting unit.
5.5.2
Power Regeneration Converter and SERVOPACK Combinations
(1) Power Regeneration Converter
(2) SERVOPACK
SERVOPACK for One Axis
Model
Unit Width
(mm)
Cooling Fan
Terminal Block
Input
Voltage
(VDC)
Input
Current
(A)
Terminal
Screw
Wire Sizes
(AWG)
Tightening
Torque
(N
x
m)
JUSP-JUBM050AA
50
24
0.42
M3.5
24 to 12
0.8 to 1.2
N
x
m
(7.1 to 10.6
lbf
x
in)
JUSP-JUBM075AA
75
0.94
JUSP-JUBM100AA
100
0.94
JUSP-JUBM150AA
150
1.88
Power Regeneration Converter
Base Mounting Unit
Input Voltage
Model
Model
Three-phase 200 VAC
CACP-JU15A3
JUSP-JUBM100AA
CACP-JU19A3
CACP-JU22A3
CACP-JU30A3
JUSP-JUBM150AA
Three-phase 400 VAC
CACP-JU15D3
JUSP-JUBM100AA
CACP-JU19D3
CACP-JU22D3
SERVOPACK
Base Mounting Unit
Input Voltage
Model
Model
270 VDC
CACR-JU028ACA
JUSP-JUBM050AA
CACR-JU036ACA
CACR-JU065ACA
JUSP-JUBM075AA
CACR-JU084ACA
JUSP-JUBM150AA
CACR-JU102ACA
CACR-JU125ACA
540 VDC
CACR-JU014DCA
JUSP-JUBM050AA
CACR-JU018DCA
CACR-JU033DCA
JUSP-JUBM075AA
CACR-JU042DCA
JUSP-JUBM150AA
CACR-JU051DCA