5.3 Magnetic Contactor for Winding Selection
5-9
Peripheral Devices
5
5.3
Magnetic Contactor for Winding Selection
5.3.1
Specifications
∗
1.
Safety covers are provided on the HV-
AP4S and HV-
AP4S/UL.
∗
2.
A dwell time of 1 hour or more is required after applying power supply for 30 minutes.
5.3.2
External Dimensions
The external dimensions are shown below.
(1) Model: HV-75AP4
Model
*1
Standard
HV-75AP4
HV-150AP4
For UL Compliance
HV-75AP4/UL
HV-150AP4/UL
Contact
Main contact: 3NO, 3NC, auxiliary contact: 1NC
Rated Insulation Voltage
600 V
Rated Applying Current
Continuous
75 A
150 A
30 minutes
*2
87 A
175 A
Breaking Current
Capacity
220 V
200 A
400 A
440 V
150 A
300 A
Open/Close Frequency
600 times/hour
Mechanical Duration of Life
5 million times
Control Magnetic Coil Rating
200 V 50/60 Hz, 220 V 50/60 Hz,
230 V 60 Hz
Mass
2.5 kg
5.0 kg
Ambient Temperature
-10 to 55
°
C
Storage Temperature
-20 to 85
°
C
Humidity
10 to 95%RH (non-condensing)
Spindle Motor Capacity (50%ED)
5.5 to 15 kW
18.5 to 30 kW
Main circuit terminals (M5)
Control circuit terminals (M4)
4-M6 mounting holes
Unit: mm
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
145
160
107
92
85
65
11
0