12 Appendix
12-26
12.2
Parameter Recording Table
Use the following table for recording parameters.
Parameter
Index
Number
Factory
Setting
Name
When
Enabled
Pn000
2000h
0000
Basic Function Select Switch 0 After restart
Pn001
2001h
*1
Application Function Select
Switch 1
After restart
Pn002
2002h
0001
Application Function Select
Switch 2
After restart
Pn006
2006h
0002
Application Function Select
Switch 6
Immediately
Pn007
2007h
0000
Application Function Select
Switch 7
Immediately
Pn008
2008h
4000
Application Function Select
Switch 8
After restart
Pn00B
200Bh
0001
Application Function Select
Switch B
After restart
Pn00D
200Dh
0000
Application Function Select
Switch D
After restart
Pn010
5C00h
0001
SERVOPACK Address (for
USB/Local bus communica-
tion)
After restart
Pn01B
2030h:1
0000
Application Function Select
Switch 1B
After restart
Pn01C
2030h:2
0000
Application Function Select
Switch 1C
After restart
Pn01E
2030h:3
0000
Application Function Select
Switch 1E
After restart
Pn01F
2030h:4
0000
Application Function Select
Switch 1F
After restart
Pn030
–
0000
Reserved (Do not change.)
–
Pn070
2030h:5
0000
Function at Cutting Feed
After restart
Pn071
2030h:6
0000
Function at Fast-forward
After restart
Pn07F
2030h:7
0000
Application Function Select
Switch 7F
After restart
Pn100
2040h:1
400
Speed Loop Gain
Immediately
Pn101
2040h:2
2000
Speed Loop Integral Time
Constant
Immediately
Pn102
2040h:3
400
Position Loop Gain
Immediately
Pn103
2060h
100
Moment of Inertia Ratio
Immediately
Pn104
2041h:1
400
2nd Speed Loop Gain
Immediately
Pn105
2041h:2
2000
2nd Speed Loop Integral Time
Constant
Immediately
Pn106
2041h:3
400
2nd Position Loop Gain
Immediately
Pn109
2061h
0
Feedforward Gain
Immediately
Pn10A
2062h
0
Feedforward Filter Time Con-
stant
Immediately
Pn10B
2065h
0000
Application Function for Gain
Select Switch
–
Pn121
2067h:1
100
Friction Compensation Gain
Immediately
∗
1.
Varies in accordance with the SERVOPACK used.
SERVOPACK CACR-JU028ACA, -JU036ACA, -JU014DCA, -JU018DCA, -JUM2
ACA, -JUM2
DCA: 0200
Other models: 0202