E
5-9
NOTE:
8
Reserve oil capacity is maximum 1,500
cm
3
(1.6 US qt, 1.31 Imp qt).
8
The oil feed pump will not operate if the
engine is tilted more than 35°. Put the
engine in the down position before oper-
ating the emergency switch.
107012
107013
107014
EMU01511
TREATMENT OF SUBMERGED
MOTOR
If the outboard motor is submerged, imme-
diately take it a Yamaha dealer. Otherwise,
some corrosion may begin almost immedi-
ately.
If you cannot immediately take the outboard
motor to a Yamaha dealer, follow the proce-
dure below in order to minimize engine
damage.
EMU00449
1)
Thoroughly wash away mud, salt, sea-
weed, etc. with fresh water.
2)
Remove the spark plugs and face the
spark plug holes downward to allow any
water, mud or contaminants to drain.
3)
Drain the fuel from the vapor separator,
fuel filter and fuel line.
4)
Feed fogging oil or engine oil through
the intake manifold and spark plug
holes while cranking with the emer-
gency starter rope.
5)
Take the outboard motor to a Yamaha
dealer as soon as possible.
c
C
Do not attempt to run the motor until it
has been completely inspected.