Chapter 6
Component Guide
DME Designer Owner’s Manual
400
Section
Parameter
Setting Range
Function
1
Input Channels
Phase
ON/OFF
Reverses the phase of each channel’s
input signal.
2
Gate Indicator
--
When the gate is open, the light turns
green. When the gate is closed, the light
turns yellow.
3
Threshold
-54 dB to ±0 dB
Sets the threshold value for each gate.
4
Hold
44.1 kHz: 110 m to 2.13 s
48 kHz: 101 m to 1.96 s
88.2 kHz: 55.1 m to 1.06 s
96 kHz: 50. 6m to 981 m
Sets the gate hold time.
The setting range may vary, depending
on the operating frequency.
5
Decay
44.1 kHz: 110 m to 46 s
48 kHz: 101 m to 42.3 s
88.2 kHz: 55 m to 23 s
96 kHz: 51 m to 21.1 s
Sets the speed for closing the gate.
The setting range may vary, depending
on the operating frequency.
6
Solo
ON/OFF
Turns solo ON. If Solo is engaged for
even one channel, all non-Solo channels
will be muted.
7
On
ON/OFF
Turns ON each channel’s input.
8
Fader
-
∞
to +10 dB
Sets the input signal level for each
channel.
9
Master Output
Gain Correct
ON/OFF
The output gain will be adjusted
according to the number of channels
being mixed.
)
On
ON/OFF
Turns ON each channel’s output.
!
Master
-
∞
to +10 dB
Sets the output signal level.