Chapter 6
Component Guide
DME Designer Owner’s Manual
452
CobraNet Input and Output
The DME8i-C/DME8o-C/DME4io-C configuration window includes [CobraNet Input] and [CobraNet
Output] blocks.
■
CobraNet
Either double-click [CobraNet Input]/[CobraNet Output] or select [Open CobraNet Editor] from the
contextual menu that appears when a component is right-clicked to open the editor.
CobraNet Input/Output Component Editor
* Select “Disable” if you intend to make settings via the CobraNet network using the CobraNet Manager, for example. In such
cases selecting “Enable” may result in incorrect settings.
Section
Name/Parameter
Range
Function
1
Setting from this Window
Disable/Enable
When “Disable” is selected settings made via
the CobraNet network take priority. When
“Enable” is selected settings made from the
DME Designer take priority.*
2
High Sampling
Mode
Input Format
Double Channel
Single
Selects the format for 88.2/96 kHz sampling
rates.
Linked to Output Format.
Output Format
Double Channel
Single
Selects the format for 88.2/96 kHz sampling
rates.
Linked to Input Format.
3
Bundle
Number
Input
0 ~ 65279
Specifies the input bundle number.
Output
0 ~ 65279
Specifies the output bundle number.
4
Serial
Channel
Rx
OFF, 1 ~ 15
Specifies the serial receive channel.
Tx
OFF, 1 ~ 15
Specifies the serial transmit channel.
5
Properties
Bit Length
Bit Off
16bit
20bit
24bit
Specifies the output bit rate.
Output is muted when “Bit Off” is selected.
6
Latency
5.33ms
2.67ms
1.33ms
Specifies the latency.
7
Advanced
-
Opens the “Advanced Settings” window.
1
2
3
4
5
6
7