Main Changes from V1.0 to V1.1
■
Main Panel Window
• Instead of the former Parameter Link function, there are now two functions: a Global Link function
that links parameters within all DMEs in a zone and a Local Link function that links parameters
within a single DME unit. (
)
• The Synchronization function can now not only send data from DME Designer to the DME unit,
but can also synchronize by reading data from the DME unit. (
• Scene Increment/Decrement and Time Adjustment can now be assigned in the GPI input
function. (
• DME unit events can now be recorded by the Event Logger function and displayed in the Event
Logger window. (
• The time for executing an event can now be set by using the Event Scheduler function.
(
)
• Parameters in the current configuration can now be listed on the display and printed out by using
the Parameter List function. (
• The Wav File Manager can manage Wave files played by the Wav File Player. (
• Settings can be made by the DAW Control function that are used for controlling DMEs from a
DAW controller. (
• DME unit data can now be saved as a backup file by using the Backup function. (
■
Designer Window
• The port name display can now be switched between long name display and short name display.
(
)
• DME64N cascade connections can now be set. (
• Priority items can now be set when compiling configurations by using the [Compile Priority]
function in the “Preferences” dialog box. (
• Delay time can now be displayed for each component by using the Show Signal Delay function.
(
)
• Monitoring points can now be edited by using the “Monitoring Point List” dialog box.
(
)
• The status of connections in a configuration can now be analyzed in advance by using the
Analyze function, without connecting the DME unit. (
• You can now set the action that occurs when you double-click a user module object. You can also
turn user module security ON or OFF, and set a password. (
)
• Libraries with component parameters saved in them can now be recalled from the context menu
• A new rule for wiring prohibits connections to terminals that would short the terminator.
■
Component Editor/Component
• A status bar has been added to the component editor. It displays the component name,
component ID, and parameter IDs for parameters that are being edited. (
)
• A Snap function has been added that records parameters in the editor temporarily. Parameter
sets can then be switched by using the Snap buttons. (
)
• The meter's peak hold function can now be turned ON or OFF. (
)
• A Wav File Player component has been added for playing Wave files. (
)
• An effect component called SPX has been added that supports many different effect
applications, such as reverb, delay, and modulation effects, along with complex combinations of
multiple effects. (