Chapter 6
Component Guide
DME Designer Owner’s Manual
428
Different numbers of channels are provided by each component variation.
Each frequency band has its own color, with Low being red, Mid being green, and so on.
Name
Function
1
Library name
Displays library name.
2
Crossover response (phase)
Crossover phase response, color coded for
output channel.
3
Crossover response (level)
Crossover level response, color coded for
each output channel.
4
Input meter
Displays the input signal level.
5
Output meter
Displays the output level for each band.
6
Crossover Curve Display Button
Turns crossover curve display for each
output channel on or off.
Section
Parameter
Range
Function
7
Delay
Delay
ON/OFF
Applies delay to the crossover response.
8
PEQ
PEQ
ON/OFF
Applies PEQ to the crossover response.
9
Navigator
Input Level
-
∞
to +10 dB
Specifies the input signal level.
)
Crossover
–
Opens the crossover editor window.
!
Delay
–
Opens the delay editor window.
@
PEQ
–
Opens the parametric equalizer editor
window.
#
Output Level
-
∞
to +10 dB
Sets the output level from each output
channel.
$
Mute
ON/OFF
Mutes the output of each output channel.
%
Limiter
–
Opens the limiter editor window.
1 Way
ALL
2 Way
Low/High
3 Way
Low/Mid/High
4 Way
Low/Low-Mid/High-Mid/High
5 Way
Sub-Low/Low/Low-Mid/High-Mid/High
6 Way
Sub-Low/Low/Low-Mid/Mid/High-Mid/High