Chapter 6
Component Guide
DME Designer Owner’s Manual
476
Initializing the ICP1
Follow the steps below to initialize the internal
memory: You can select one of the following
initialization types:
* Initializing the current scene backup [CURRENT
BACKUP]
* Initializing all user settings (excluding the libraries)
to the factory settings [WITHOUT LIB.]
* Initializing all settings to the factory settings
[FACTORY SETUP]
1.
Turn off the power to the ICP1.
2.
Plug the PA-300 AC adaptor while holding
down the [SCENE] and [ENTER] buttons.
Release keys after YAHAMA logo disappears.
The Initialization display appears.
3.
Press the [F2]/[F5] keys to select a type of
initialization.
Initialize DME:
Deletes all user settings except component data.The
Utility settings will be set to default values.
Delete All Data:
Component data will be deleted. The Utility settings
will be set to default. After initialization, transfer
necessary components from DME Designer.
==> Exit Diag Mode:
Leaves this screen and restarts.
4.
Press the [ENTER] key.
Do not turn off the power during initialization. Doing so
can damage the device.
When the internal memory is initialized, all data
stored in the memory will be lost. Use caution when
you execute this function.
NOTE
To cancel the initialization operation, select “==> Exit Diag
Mode” and confirm the cancellation. Alternatively, simply turn
off the power to the ICP1.
CAUTION