87
SPARES INSTALLATION GUIDE (CONTINUED)
Syrup Pump
Location:
Fixed to the syrup pump bracket on the front cover of the
carbonator unit
1.
Isolate the mains at the power supply.
2.
Remove the lid.
3.
Disconnect the syrup tubes from the syrup pump.
4.
Remove the pump from the syrup pump bracket by undoing the 2 fixing
screws (these can be undone by pocking long Posi-screwdriver through
the holes on the back panel).
5.
Disconnect the electrical connection to the pump.
6.
Lift the pump clear of the unit.
7.
Installation is the reversal of the removal process.
Thermostat
Location:
Fixed to the left on the back pane of the carbonator unit
1.
Isolate the mains at the power supply.
2.
Remove the thermostat.
3.
Remove the thermostat phil from the heat exchanger phil pocket
4.
Installation is the reversal of the removal process.
Summary of Contents for Eco Encore
Page 1: ...Eco Encore Solo Encore Technical Manual...
Page 141: ......
Page 142: ......
Page 143: ......