107
Error code 57 - Over Temperature Trip.
GRAPH OF RESISTANCE VERSUS TEMPERATURE
0
10
20
30
40
50
60
70
80
90
100
800
900
1K
1K1
1K2
1K3
1K4
1K5
1K6
1K7
Sleep
Temperature
Operating
Temperature
Over
Temperature
Under
Temperature
SWITCH MACHINE OFF
Set your voltmeter to measure
continuity
Check for continuity across
the boiler fill switch (top
switch located on the boiler
lid), does opening and closing
the switch make and break
continuity?
Replace boiler fill
switch (P/N
100013106)
N
Check continuity
across SKT 4/6
(Grey/Blue) and SKT
4/1 (White/Red) with
the switch in its full
position, is continuity
measured?
Y
N
Locate break
within the loom
Y
Remove SKT5 from the processor and measure the
resistance across pin 1 (Yellow) and pin 2 (White). Does
the resistance correspond to the water temperature (refer
to graph of resistance verses temperature chart)
Replace over
temperature probe
(P/N 100021040)
N
Y
Are the temperature
addresses set correctly?
Reset temperature
within the
programming
N
Replace processor
board (P/N
190010)
Y
NOTE: ALLOW 3
°
C DIFFERENTIAL BETWEEN BOILER
TEMPERATURE AND WATER TEMPERATURE AT MIXING BOWL