FAULT FINDING - CARBONATOR
PROBLEM
CAUSE
SOLUTION
EXCESS FOBBING/
OVERFLOWING CUP
CARBONATED
DRINK
LOW LEVEL IN THE
CUP [CARBONATED
DRINKS]
LOW LEVEL IN THE
CUP [STILL DRINKS]
Too much
product for size
of cup.
CO2 pressure
too high.
Too much
syrup.
Temperature
too high.
CO2 cylinder
empty.
CO2 regulator
faulty.
Dispense time
too short
Carbonator not
filling correctly.
Insufficient
water pressure.
Water pump not
working.
Pump working -
pressure low.
Intermittent
freezing.
Adjust dispense time
Reset CO2 Regulator 50psi.
Reset drink strength.
Dispense tube dirty. Clean with ‘Sanitiser’.
Check the airflow over the unit condenser and
clean if necessary, or carry out ‘fridge check (see
REFRIGERATION SYSTEM TEST
PROCEDURE).
Change cylinder.
Check and replace if unable to reset to 50psi
Reset dispense times - nominally
5.0 seconds for carbonated water &
3.0 seconds syrup.
(See POOR CARBONATION)
Check mains water supply - minimum 20psi.
Check filter cartridge (if fitted), replace if
necessary.
Check that pump works on dispense of drink.
Check electrical connections to carbonator PCB
control box
Fit gauge to discharge and check dead head
pressure (125psi).
(See REFRIGERATION SYSTEM TEST
PROCEDURE)