13
4. POWERING UP THE MACHINE
REMOVE 12.5A HEATER FUSE (AND 5A COOLER FUSE IF FITTED) AS A
PRECAUTION AND THEN PULL OUT THE SERVICE SWITCH TO POWER UP
THE MACHINE.
On powering-up the machine the boiler will begin to fill. Although the heater is
protected by means of a low level switch, removal of the heater fuse, while not
essential, is recommended as good practice.
If a hot drink selection is made during the initial heating period, the display will
count down in seconds the total time before a hot drink maybe vended.
At Westomatic we carry out a fully functional test using water, which
passes through a dosing system to provide a suitable microbiological
condition. It is therefore advisable to allow the boiler to fill with water,
switch your machine off and fully drain.
5. COMMISSIONING THE CARBONATOR UNIT (IF FITTED)
1. With the machine switched off
2. Connect the cylinder, ensuring that the interface washer between the
cylinder and the regulator is in place and purge the carbonator bowl through
the relief valve for approximately 2 seconds. Check that the gas regulator is
set at 50 psi and adjust if necessary.
3. Switch machine on.
4. Enter ‘flush mode’ and flush the still then the carbonated water selections
5. Place the syrup dip-tubes into the product containers making sure that the
correct flavours correspond to the machine selection panel.
6. Prime the syrups through the nozzles in ‘flush’ mode.
NOTE:
After commissioning, it will take the refrigeration system approximately 20
minutes to achieve operating temperature, dependant on ambient conditions.
6. COMMISSIONING THE CHILLER UNIT (IF FITTED)
The Chiller unit within the Solo Encore does not require an ice bath. To
commission the Chiller unit simply enter into Flush mode and flush cold water
through the system. For more information on ‘Flushing’ see ‘Using the External
Keypad’ section.
7. SET-UP MACHINE OPTIONS
See ‘Programming’ section on machine set up to configure for payment system
etc.
8. DRINK SET-UP OPTIONS
The machine will be programmed for the standard range of drink selections,
you should however, verify that the programming settings meet the
requirements of this installation.