BOILER SLEEP TEMPERATURE – Address 116
It is recommended that the contents of this Address should remain at the
default setting and should only be altered if advised to do so by the machine
supplier.
AUTO SLEEP DELAY – Address 117
This is the amount of time, set in hours, before the boiler will go into ‘sleep’
mode (power save!) following a vend cycle.
BOILER TEMPERATURE READING – Address 118
This address displays the temperature of the boiler.
BOILER TEMPERATURE OVERFLOW READING – Address 119
If the Solo Encore boiler overfills and an error code ‘57’ is displayed, this
address will display the actual temperature of the water that has passed
through the overflow pipe. This will help in determining weather the fault had
been caused by the boiler overheating, the machine being tilted, or the boiler
switches not registering when the boiler should be full.
BOILER TEMPERATURE MAXIMUM READING – Address 120
This address will display the highest temperature that the boiler has reached
prior to an error code being displayed and should be used in conjunction with
address 119.
BOILER FILL TIMEOUT – Address 121
The time set within this address determines the amount of time the machine
‘calls’ for water before switching off if the boiler has not registered as being full.
BOILER TEMPERATURE EXCEED TIMEOUT – Address 122
The time set within this address determines how long the boiler can exceed the
operating temperature before highlighting a fault.
Note: The boiler will fluctuate around 2
o
C of the operating temperature.
BOILER HEAT ON TIMEOUT – Address 123
The time set within this address determines how long the processor will sustain
an output to the boiler relay before switching it ‘off’ if the boiler has not reached
its operating temperature.
BOILER TEMPERATURE OVERFLOW TRIP TEMPERATURE – Address 126
Displays the overflow temperature at time of peak during an Error 57 event.