52
TABLE OF FIELD PARAMETERS
The Solo Encore provides the ability to fully configure your drink for optimum taste. A
selection of the addresses within the Solo Encore have ‘multiple parameters’, this
provides the user with the ability to set timings for specific drinks and also allows the
drinks to be ‘pulsed’ for a fuller flavour.
Listed below is a table outlining the data field parameters and over the page
are two examples of how to use the parameters within your programming.
Keys Description
Data
Field
[1]
Data
Field
[2]
Data
Field
[3]
Data
Field
[4]
Data
Field
[5]
Data
Field
[6]
Data
Field
[7]
Data
Field
[8]
Comments
Prices
Used for
Price entries
Regular
Price
Large
Price
All price addresses have
2 data fields
Set-up
Used for
Drink
Set up
Basic
Set-up
Extended
Set-up
Countdown
Extra Time
(Sec) –
Black Only
Countdown
Extra Time
(Sec) -
Black
+
Sugar
Countdown
Extra Time
(Sec) –
White Only
Countdown
Extra Time
(Sec) -
White
+
Sugar
Used for setting
individual drink
selections. All main set
up addresses have 3
data fields
Throws
Used for
Editing
Normal
Drink throws
Regular
Throw
Throw
Delay
Large
Throw
Pulse
on time
Pulse
off time
Used for setting
individual throw times.
All throw addresses
have 3 data fields Pulse
fields are limited to a
maximum value of 5.0
seconds
Piston
Time
Used for
FB Piston
push
Black Only
Black
+
Sugar
White
Only
White
+
Sugar
Large
Black only
Large
Black
+
Sugar
Large
White Only
Large
White
+
Sugar
Used for setting
individual piston push
times (ASD) for different
drink additions. All
Piston addresses have 8
data fields
Extra
Water
Used for
Individual
water Top-
ups
Black Only
Black
+
Sugar
White
Only
White
+
Sugar
Large
Black Only
Large
Black
+
Sugar
Large
White Only
Large
White
+
Sugar
Used for adding extra
top up water for different
drink additions. All Extra
water addresses have 8
data fields
Syrup
Topping
Used to set
syrup
topping
throw
Regular
throw
Throw
Delay
Large
Throw
Pulse, On
Time
Pulse,
Off Time
Syrup
Source
Used for setting Syrup
throw times. All Syrup
throw addresses have 6
data fields Pulse fields
are limited to a
maximum value of 5.0
Seconds
Payment
Type
Used to set
up payment
systems
Coin
Type
Bill
Type
Used for setting different
payment devices for
configuring coins or
notes for validator’s or
mech’s. Addresses 202-
217
Note: Data fields 4 and 5 (Pulse time on and off) are active on Bean to Cup models
as standard. The purpose of pulsing a water solenoid valve and/or an
ingredient/whipper motor is to provide a continual body of flavour throughout the
process of vending the drink. To ensure trouble free vending the pulse on and pulse
off times should be set the same and must not fall below 5 seconds.