19.4 Operations to carry out
1 Enrol the control panel (see paragraph 120) Note: It is presumed that the comfort and intrusion detection
alarm systems have first been installed and configured for local control
2 Enable remote control of the temperature zones, to be done on the comfort control panel (see instructions
manual of the control panel)
3 Enable remote control of the scenarios, to be done on the comfort control panel (see instructions manual of
the control panel)
4 Enrol the temperature zones 1 and 2 of the control panel using the automatic procedure (recommended,
considering the system configuration), or the manual one:
- Automatic: temperature zone 1 of the control panel will be associated with “thermostat 1” (C1) of the
GSM communicator and temperature zone 2 of the control panel will be associated with “thermostat 2”
(C2) of the GSM communicator (see paragraph 1231)
- Manual: read the address of the control unit using its menu and make the association of temperature
zone 1 with “thermostat 1” and temperature zone 2 with “thermostat 2” (see paragraph 1232 in this
manual and the control panel manual)
5 Customizing the two associated thermostats with an SMS text message
By default “thermostat 1” has the label SMS “C1”, while “thermostat 2” has the label “C2” (see paragraph
1311)
6 Enrol the scenarios 1 and 2 of the control panel using the automatic procedure (recommended, considering
the system configuration) or the manual one:
- Automatic: scenario 1 of the control panel will be associated with “scenario 1” (SC1) of the communicator
and scenario 2 of the control panel will be associated with “scenario 2” (SC2) of the GSM communicator
(see paragraph 1271)
- Manual: read the address of the control unit using its menu and make the association of scenario 1 with
“scenario 1” and scenario 2 with “scenario 2” (see paragraph 1272 and the control panel manual)
7 Customizing the two associated scenarios with an SMS text message By default “scenario 1” has the label
SMS “SC1”, while “scenario 2” has the label “SC2” (see paragraph 1321)
8 Enrol groups 1 and 2 of the control panel using the manual procedure:
- read the address of the control unit and the index of group 1 and make the association of “group 1”
(GR1) of the GSM-BUS Communicator 01942, and similarly for “group 2” (GR2) (see paragraph 12111
and the control panel manual)
9 Customizing the two associated groups with an SMS text message
By default “group 1” has the label SMS “GR1”, and “group 2” has the label “GR2” (see paragraph 1351)
10 Configure the number of phone1 (paragraph 93)
11 Associate the phone number 1 with the group fo voice messages of the instrusion alarm: “
VOCAI
” (para-
graph 95)