General Configuration
13.4 Technical alarm
The GSM-BUS 01942 Communicator is able to manage at most 8 groups of technical alarms from contract
interfaces of VIMAR home automation or SAI systems
Technical alarm warnings require configuring the communicator, setting the origin of the alarm This setting dif-
fers depending on whether the contact interface belongs to a SAI system managed by one of the control panels
20480, 16930, 14480 or by another VIMAR control panel:
Control panels 20480, 16930, 14480:
the GSM-BUS communicator 01942 must be given the address of the
group of the contact interface generating the technical alarm to configure
This address can be viewed via the menus of the control panels and is represented with hexadecimal notation
The address to supply to the GSM communicator 01942 can be viewed by following the path:
Configuration
Device management
Parameters
OK
<select the desired contact
interface device>
ID group
<Object On_Off>
(that is type 0xABCD, with A,B,C,D digits repre-
sented in hexadecimal form)
Control panels 01950, 01951, 01952, 01956, 01958, 01960:
the GSM-BUS communicator 01942 must be
given the address of the group of the contact interface generating the technical alarm to configure
This address can be viewed via the menus of the control panels and is represented with hexadecimal notation
If the interface generating the technical alarm belongs to the automation system, the address to supply to the
GSM communicator 01942 can be viewed by following the path:
Control Panel Setup
Configuration
Group Management
Automation
<select techni-
cal alarm group>
Info
<Group address>
(that is type 0xABCD, with A,B,C,D digits represented
in hexadecimal notation)
If the interface generating the technical alarm belongs to the intrusion detection alarm system, the address to
supply to the GSM communicator 01942 can be viewed by following the path:
Control Panel Setup
Configuration
Group Management
Intrusion Detection Alarm
System
<select technical alarm group>
Info
<Group address>
(that is type 0xABCD, with
A,B,C,D digits represented in hexadecimal notation)
Control panels 20510, 16950, 14510:
the GSM-BUS communicator 01942 must be given the address of the
group of the contact interface generating the technical alarm to configure
This address can be viewed via the menus of the control panels and is represented with hexadecimal notation
The address to supply to the GSM communicator 01942 can be viewed by following the path:
Menu
Configuration
Group Mgt.
<identify technical alarm group>
<Read group
address>
(type [ABCD], with A,B,C,D digits represented in hexadecimal notation, which must be supplied
to the communicator in the form 0xABCD)