25
Alarm warning - Configuration of the bus interface
10. Alarm warning
The GSM-BUS Communicator manages voice and SMS alarm messages that can be associated with up to 8
phone numbers
The alarm warning procedure is the following:
• The procedure of
SENDING -ALARM SMS
: the communicator checks there are the phone numbers associ-
ated with the SMS message and then sends these numbers an SMS If there are no associated phone num-
bers, the SMS message will not be sent
• The procedure of
SENDING VOICE MESSAGE
: the communicator checks there are the phone numbers
associated with the voice message and starts up the following procedure:
1 It sends the message to the first phone number If the user replies, the message is duplicated and the user
code is requested;
2 If the user enters the correct code, the procedure ends; the GSM Communicator ends the communication
and deletes the alarm status of the system on the GSM-BUS communicator;
3 If the user enters an incorrect code, it hangs up during the alarm warning or does not answer the call
If there is a following phone number, the GSM-BUS Communicator waits 30 seconds and then restarts
the procedure for sending the voice message from the next phone number If there is no following phone
number, the communicator waits 90 seconds and restarts from point 1
4 After the third cycle of sending the voice message to all the associated phone numbers, the communicator
cancels the alarm status If there are no associated phone numbers, the voice message will not be sent
11. Configuration of the bus interface of the communicator and pre-
liminary operations on the By-me control panels.
11.1 BUS interface configuration.
The bus interface of the 01942 communicator must be learned by the control panel using the specific menu
From the point of view of the By-me control panel, the operation to perform is exactly the same one used for
learning the interface 01848 (refer to the control panel instructions manual) The push-button and the “BUS”
LED of the GSM-BUS communicator 01942 have the same functions as the push-button and LED of the
01848 interface
11.2 Preliminary configurations for remote control of the intrusion detection alarm
system.
If the intrusion detection alarm system is governed by one of the control panels 20480 (SW version 40 or high-
er), 16930 (SW version 40 or higher), 14480 (SW version 40 or higher), 01950, 01951, 01952, 01956, 01958
or 01960 for the GSM-BUS communicator to be able to access the intrusion detection alarm system from a
remote location it is necessary to run the Phone Communicator configuration procedure from the specific menu
of the control panel (see instructions manual of the control panel