AC70 VC CONTROL FREQUENCY INVERTER MANUAL
FUNCTION PARAMETER DETAILED SPECIFICATION
90
Input terminal OFF/ON state schematic diagram
Output terminal OFF/ON status schematic diagram
2: Fault information inquiry
After inquiry setting, digital LED display below table information. Recycling shows is available via press up and
down keys.
Serial
number
Definition
Remark
Commu
nication
code
Er.01
The latest fault information
Refer to fault information code to get
more in detail
E01H
Er.02
The cumulative running time before the
latest fault
Units: hour
E02H
Er.03
Output frequency while the latest fault
Units: Hz
E03H
Er.04
DC bus voltage while the latest fault
Units: V
E04H
Er.05
Output current while the latest fault
Units: A
E05H
Er.06
Output voltage while the latest fault
Units: V
E06H
Er.07
Module temperature while the latest fault
Units:
℃
E07H