AC70 VC CONTROL FREQUENCY INVERTER MANUAL
PERIODIC OVERHAUL AND MAINTENANCE
62
●
Fan
While changing fan, please use original fan. You can contact Veichi company or the dealer. There are inverter models
with many fans in one machine. To prolong these machines lifetime, you had better change all fans while changing the
cooling fan.
●
Fan change method
:
1, Install the fan vertically into the cover as shown in the picture (the label should face the outside).
2, Press the elastic clip of the fan by finger toward the inner side and insert the leading terminal of the fan vertically by a
little strength.
3, Insert the two elastic clips of the fan cover vertically into the fan installation slots.