AC70 VC CONTROL FREQUENCY INVERTER MANUAL
APPENDIX
125
External terminal parameters
Code
function
Function name
Setting range and define
Factory
default
pr
op
ert
y
Refe
r to
page
Comm
unicati
on
code
F-01
Input signal selection 1
(
X1
)
0: Invalid
1: Forward jog operation
2: Reverse jog operation
3: Free stop
4: Fault reset
5: Multi steps speed control 1
6: Multi steps speed control 2
7: Multi steps speed control 3
8: Multi steps speed control 4
9: UP/Down running frequency
increasing UP
10:UP/Down running frequency
decreasing DW
11: Three wire operation control D
(X)
12: PID control cancel
13: External fault alarm
14: Acceleration/deceleration time
selection terminal 1.
15:Acceleration/deceleration time
selection terminal 2
16: Frequency main channel
selection terminal 1
17: Frequency main channel
selection terminal 2
18: Frequency main channel
selection terminal 3
19: Frequency main channel
selection terminal 4
20: Program running pause
21: Program restart
22: Timer trigger terminal
23: Timer reset terminal
24: Counter reset terminal
25:Counter clock input terminal
26:Only terminal control channel is
enabled selection
27: Forward running
28: Reverse running
27
〇
93 201H
F-02
Input signal selection2
(
X2
)
28
〇
93 202H
F-03
Input signal selection 3
(
X3
)
1
〇
93 203H
F-04
Input signal selection 4
(
X4
)
2
〇
93 204H
F-05
Input signal selection 5
(X5
)
3
〇
93 205H
F-06
Input signal selection 6
(
X6
)
4
〇
93 206H